Given Imaging Ltd. Bravo CF capsule delivery device, 5-pack recall: Capsule may fail to attach to the esophagus or detach from the delivery
Capsule may fail to attach to the esophagus or detach from the delivery device. Risks include patient aspiration/inhalation, perforation of esophagus, obstruction of the airway, hemorrhage/blood loss/bleeding, laceration of the esophagus, a delay in diagnosis, and foreign bodies remaining in the patient.
The hazard: Laceration or amputation hazard
This recall is about a cutting injury: a blade, edge or part that can reach the user when it should not.
What the notice says: Capsule may fail to attach to the esophagus or detach from the delivery device. Risks include patient aspiration/inhalation, perforation of esophagus, obstruction of the airway, hemorrhage/blood loss/bleeding, laceration of the esophagus, a delay in diagnosis, and foreign bodies remaining in the patient.
Why it matters: A blade, edge or moving part can cut the user, or a part can break and come apart in the hand. With powered tools, the same defect that causes a cut can cause a much worse injury.
Symptoms and when to call a doctor
Control bleeding with firm, direct pressure using a clean cloth and raise the limb if you can. Go to an emergency department for a wound that will not stop bleeding, that gapes open, that is deep or dirty, that involves a hand, face or joint, or where feeling or movement has changed. If a body part has been severed, call 911, wrap the part in clean damp gauze, seal it in a bag and keep the bag on ice — never directly on ice.
This page is general information, not medical advice. If you feel unwell, a clinician who can see you is the only person able to judge your case.
Recall details
- Recall number
- Z-3090-2026
- Published
- September 16, 2026
- Risk level
- Class I
- Status
- Ongoing
- Issued by
- U.S. Food and Drug Administration
- Brand
- Given Imaging Ltd.
- Product type
- Medical devices
- Units affected
- 127,416
- Distribution
- Nationwide
- Made in
- Israel
- Lot / code info
- Product Number FGS-0635 UDI-DI (GTIN) 07290101369707 Product Number FGS-0636 UDI-DI (GTIN) 07290101369714 Expiration dates prior to and including October 20, 2027 (lot numbers from 64553F up to and including 68912F)
- UPC codes
- 07290101369707, 07290101369714
Products covered by this recall
Bravo CF capsule delivery device, 5-pack, Product Number FGS-0635, Bravo CF capsule delivery device, 1-pack, Product Number FGS-0636. Used to attach a pH monitoring capsule to the esophagus.
Check your product
The notice names 11 codes you can read straight off the package. Type the one printed on yours and the list below narrows to it.
UPC / barcode
Read the twelve digits under the barcode on the package.
- 07290101369707
- 07290101369714
Lot or batch code
Usually ink-stamped near the seam, the cap or the bottom of the pack.
- from 64553F up
- including 68912F
Best-by / use-by date
Printed beside the lot code, not on the price sticker.
- including October 20
Model or item number
On the rating label, the box or the instruction sheet.
- FGS-0635
- 1-pack
- FGS-0635 UDI-DI
- FGS-0636 UDI-DI
Package size
Match the net weight or the piece count on the front of the pack.
- 5 pack
- 1 pack
Codes are lifted verbatim from the FDA — Device enforcement notice. A code that is missing here may still be covered — the official notice is the complete list.
What to do about Laceration
Given Imaging Ltd. — This recall is about a cutting injury: a blade, edge or part that can reach the user when it should not.
- Stop using the product and unplug it, or take the battery out if it is cordless.
- Follow the remedy on this page and keep the receipt or order confirmation if you have one.
- Do not try to grind off, tape over or otherwise work around a sharp part — you cannot restore the guard the design is missing.
- Keep it away from children, and from anyone else in the household who might pick it up without knowing.
Claiming your refund, repair or replacement
The recalling company decides the remedy and funds it. You should never pay for a recall repair or for return shipping.
- Use the company contact on this page first. Most firms run a dedicated recall page with a claim form that is far quicker than their main support line.
- If you bought it from a retailer rather than the brand, try both. Target, Walmart and Amazon often refund recalled goods from the order history.
- If the company stops responding, escalate to the CPSC. Firms under a recall order have reporting duties to the agency.
- Have the model number, the date code and your photos ready. Many companies issue store credit by default — ask for cash or a card reversal if you would rather have it.
Company contact: Given Imaging Ltd. — New Industrial Park, Yokne'Am Ilit
The official notice
This page summarises a notice published by U.S. Food and Drug Administration. The agency notice is the authoritative version — read it before you act, and treat it as the final word if anything here looks different.
Open the FDA — Device enforcement record U.S. Food and Drug Administration recalls
Questions people ask about this recall
Why was Given Imaging Ltd. medical devices recalled?
Capsule may fail to attach to the esophagus or detach from the delivery device. Risks include patient aspiration/inhalation, perforation of esophagus, obstruction of the airway, hemorrhage/blood loss/bleeding, laceration of the esophagus, a delay in diagnosis, and foreign bodies remaining in the patient. Capsule may fail to attach to the esophagus or detach from the delivery device. Risks include patient aspiration/inhalation, perforation of esophagus, obstruction of the airway, hemorrhage/blood loss/bleeding, laceration of the esophagus, a delay in diagnosis, and foreign bodies remaining in…
How do I know if I have the recalled product?
Match the codes printed on your package against the notice: UPC 07290101369707, 07290101369714; lot code from 64553F up, including 68912F; best-by date including October 20; model number FGS-0635, 1-pack, FGS-0635 UDI-DI. If the code on your package is not on that list, your unit is outside the recall.
What should I do with it right now?
Stop using the product and unplug it, or take the battery out if it is cordless.
Can I get my money back?
Use the company contact on this page first. Most firms run a dedicated recall page with a claim form that is far quicker than their main support line.
Where was the recalled product sold?
It was distributed nationwide.
Related recalls
-
Class II · 11 days ago
Stryker Sustainability Solutions Bard EP XT Decapolar Steerable recall: Diagnostic electrophysiology (EP) catheter may have a breached sterile
Diagnostic electrophysiology (EP) catheter may have a breached sterile barrier on the straight seal side of the primary pouch, which if used could…
-
Class II · 11 days ago
Steris Corporation Verify Biological Steam Test Pack Model/ recall: Geobacillus stearothermophilus spore population in affected products may fall
Geobacillus stearothermophilus spore population in affected products may fall below minimum shelf life specification. When used to monitor steam…
-
Class II · 11 days ago
Medtronic MiniMed, Inc. Brand Name: MiniMed Flex Product Name: MiniMed Flex Insulin recall: Some MiniMed Flex insulin pumps were released with missing (i.e
Some MiniMed Flex insulin pumps were released with missing (i.e., devices with no result or abort test results are presumed to have failed) or failed…
-
Class II · 11 days ago
Philips Medical Systems Spectral CT and Spectral CT 7500 RT recall: Software issues may affect the safety and performance of Spectral CT
Software issues may affect the safety and performance of Spectral CT system(s). The issues may result in image artifacts, wrong slice thickness, or…
-
Class II · 11 days ago
Medline Industries, LP Rollator, Bariatric, Basic Steel, Blue recall: The front fork stem bolt/wheel assembly may disconnect from the rollator
The front fork stem bolt/wheel assembly may disconnect from the rollator frame tubing. If the front fork stem bolt/wheel assembly disconnects from…
-
Class II · 11 days ago
Onkos Surgical Inc. My3D recall: Personalized pelvic implants inadvertently mixed up and distributed
Personalized pelvic implants inadvertently mixed up and distributed to incorrect customers.