Metrix, Baxter Empty IV flexible containers recall: Potential for leaking of the IV bag at the chamber divider rod
Potential for leaking of the IV bag at the chamber divider rod
The hazard: Device safety concern
A device recall was filed for this product. For anything implanted or relied on daily, the clinician comes before the paperwork.
What the notice says: The Metrix Company of Dubuque, Iowa is recalling specific lots of the empty IV flexible containers (bag) marketed under the Metrix Secure EVA Dual Chamber and Baxter ExactaMix names, due to the potential for leaking of the IV bag at the chamber divider rod, which could result in a serious infection to the patient.
Why it matters: The FDA recorded an enforcement action against this device. Most device recalls are corrections rather than removals, so the device often stays in use while the manufacturer issues a fix.
Recall details
- Published
- September 9, 2019
- Risk level
- Elevated risk
- Issued by
- U.S. Food and Drug Administration
- Brand
- Metrix, Baxter
- Product type
- Medical devices
- Distribution
- Nationwide
- Reports of harm
- No reports of death, illnesses or injuries have been reported to date from the use of this product.
Products covered by this recall
Empty IV flexible containers (bag)
What the company announced
The Metrix Company of Dubuque, Iowa is recalling specific lots of the empty IV flexible containers (bag) marketed under the Metrix Secure EVA Dual Chamber and Baxter ExactaMix names, due to the potential for leaking of the IV bag at the chamber divider rod, which could result in a serious infection to the patient.
These bags are used for use in an intravenous admixture program, to store and deliver intravenous parenteral admixtures to patients. The empty bag is filled with parental admixtures by a healthcare provider (e.g. licensed pharmacist) under normal pharmacy conditions, e.g. laminar flow hood.
- Product Name: 1500 ml EVA Dual Chamber Bag – ExactaMix · Product Code: H938901 · Lot Number(s): 63615- A1768, A1770, A1772, A2648, A2650, A2652, A2653, A2654, A2656, A2658, A2660, A2662, A3951, A3953, A3955, A3958, A3960, A3962, A3964, A3966, A3967, A5337, A5339, A5341, A5343, A5345, A5347, A5349
- Product Name: 3000 ml EVA Dual Chamber Bag – ExactaMix · Product Code: H938905 · Lot Number(s): 63630- A1769, A1771, A1773, A2647, A2649, A2651, A2655, A2657, A2659, A2661, A3950, A3952, A3954, A3956, A3957, A3959, A3961, A3963, A3965, A3968, A5338, A5340, A5342, A5344, A5346, A5348, A5350
- Product Name: 1500 ml EVA Dual Chamber Bag - with Manifold · Product Code: 66616 · Lot Number(s): A2442, A2524, A2725, A2906, A2974, A3033, A3309, A3310, A3318, A3520, A3554, A3559, A3737, A3773, A3794, A3977, A4081, A4147, A4443, A4516, A5064, A5281, A5410, A5550, A5669
- Product Name: 3000 ml EVA Dual Chamber Bag - with Manifold · Product Code: 66631 · Lot Number(s): A2443, A2564, A2629, A2772, A2975, A3004, A3311, A3456, A3483, A3553, A3558, A3738, A3774, A3795, A3978, A4082, A4148, A4444, A4517, A5065, A5282, A5411, A5555, A5670
- Product Name: 4000 ml EVA Dual Chamber Bag - with Manifold · Product Code: 66641 · Lot Number(s): A2630, A2683, A3005, A3560, A3796, A3979, A4220, A4473, A4543, A5066, A5283, A5412, A5556, A5671
- Product Name: 1500 ml EVA Dual Chamber Bag – Legless · Product Code: 66615 · Lot Number(s): A3539, A5098
- Product Name: 3000 ml EVA Dual Chamber Bag – Legless · Product Code: 66630 · Lot Number(s): A2771, A4282
- Product Name: 4000 ml EVA Dual Chamber Bag – Legless · Product Code: 66640 · Lot Number(s): A2404, A4324
These products were supplied to distributors throughout the United States and Canada from 11/01/2016 thorough 07/29/2019.
The product code and lot number can be identified on the outer box label on the cardboard carton and on the outer bag label. The complete product identifier consists of a 5-digit product code with a unique 5-digit lot number after the hyphen.
The recall was initiated after receipt of eight complaints of leaking bags, in which the leak occurred near the divider rod and channel, when the rod was being removed. Use of the defective product, with a breach of the sterile barrier could result in serious infection to the patient. Subsequent investigation indicates the problem was caused by the assembly machine malfunction, creating additional stress on the rod, channel and bag film resulting in a potential to cause a material anomaly that is concealed until the rod is removed at the point of use.
No reports of death, illnesses or injuries have been reported to date from the use of this product.
Metrix is working with distributors and consumers to facilitate prompt return and replacement of the product affected by this recall, to minimize impact on patient therapy. Pharmacies who have purchased EVA Dual Chamber containers (bags), are urged to contact their distributor for further instructions on the return, see table for a complete list of product codes and lot numbers affected.
Therefore:
Patients are urged to immediately inform their Healthcare Provider, if they observe a leaking bag. If a patient observes a leak, DO NOT INFUSE THE BAG
Healthcare Providers should consult with the patient and determine the benefit / risk of continuing the use of a recalled product versus awaiting replacement product. Healthcare Providers should inform the Pharmacist who dispensed the product, of the leaking bag.
If the recalled product is intended for immediate use, and there is no alternative, your Healthcare Provider will make a determination on the risk/benefit associated with you using the potentially non-sterile product.
If product is not for immediate use, immediately discontinue use of the product and contact the place of purchase or pharmacy for further instructions for returning and replacing the affected product.
Consumers with questions about this recall, including facilitating replacement product, may contact The Metrix Company at 1-800-752-3148, Monday through Friday, 8:00 AM to 5:00 PM Central time or email; [email protected] . The Metrix Company regrets any inconvenience this may cause and is committed to patient safety and customer satisfaction.
Adverse reactions or quality problems experienced with the use of this product may be reported to the FDA's MedWatch Adverse Event Reporting program either online, by regular mail or by fax.
Complete and submit the report Online
Regular Mail or Fax: Download form or call 1- 800-332-1088 to request a reporting form, then complete and return to the address on the pre-addressed form, or submit by fax to 1-800-FDA-0178
Reproduced from the company announcement posted on fda.gov. Links and contact forms in the original are not repeated here; the official notice below has them.
Check your product
The notice names 11 codes you can read straight off the package. Type the one printed on yours and the list below narrows to it.
Model or item number
On the rating label, the box or the instruction sheet.
- H938901
- H938905
- 66616
- 66631
- 66641
- 66615
- 66630
- 66640
Package size
Match the net weight or the piece count on the front of the pack.
- 1500 ml
- 3000 ml
- 4000 ml
Codes are lifted verbatim from the FDA — Company recall announcements notice. A code that is missing here may still be covered — the official notice is the complete list.
What to do about Device
Metrix, Baxter — A device recall was filed for this product. For anything implanted or relied on daily, the clinician comes before the paperwork.
- Match the model, catalogue, lot and serial numbers on your device against the identifiers on this page.
- Ask the supplier or clinic that provided it what the remedy is in your case.
- If you are a facility, quarantine affected stock and log the correction.
- Report device problems to the FDA through MedWatch.
Claiming on a recalled device
Device recalls are tracked by serial and lot number, so your claim moves faster if you lead with those.
- Have the model, catalogue, lot and serial numbers ready before you call — they are on the device label or its box.
- Ask explicitly whether your unit is in the affected range; many recalls cover only part of a model line.
- If you need the device daily, ask what interim arrangement they offer while the remedy is carried out.
- Log the date, the name and the reference number of every call. Device recalls can run for months.
Remedy named in the notice: Metrix is working with distributors and consumers to facilitate prompt return and replacement of the product affected by this recall, to minimize impact on patient therapy.
Company contact: The Metrix Company — Consumers: Michael Regan, 1-800-752-3148, [email protected]
The official notice
This page summarises a notice published by U.S. Food and Drug Administration. The agency notice is the authoritative version — read it before you act, and treat it as the final word if anything here looks different.
Open the FDA — Company recall announcements record U.S. Food and Drug Administration recalls
Questions people ask about this recall
Why was Metrix, Baxter medical devices recalled?
Potential for leaking of the IV bag at the chamber divider rod The Metrix Company of Dubuque, Iowa is recalling specific lots of the empty IV flexible containers (bag) marketed under the Metrix Secure EVA Dual Chamber and Baxter ExactaMix names, due to the potential for leaking of the IV bag at the chamber divider rod, which could result in a serious infection to the patient.
How do I know if I have the recalled product?
Match the codes printed on your package against the notice: model number H938901, H938905, 66616. If the code on your package is not on that list, your unit is outside the recall.
What should I do with it right now?
Match the model, catalogue, lot and serial numbers on your device against the identifiers on this page.
Can I get my money back?
The notice says: Metrix is working with distributors and consumers to facilitate prompt return and replacement of the product affected by this recall, to minimize impact on patient therapy.
Where was the recalled product sold?
It was distributed nationwide.
Related recalls
-
Class II · 10 days ago
Howmedica Osteonics Corp. TS Universal Baseplate Finishing Tray, Triathlon recall: Reprocessing instructions provided in LSTPI-B specify a sterilization dry
Reprocessing instructions provided in LSTPI-B specify a sterilization dry time of 30 minutes for the trays sterilized in blue wrap. When blue wrap is…
-
Class II · 10 days ago
Ferno-Washington Inc Power F2 Powered Fastening System, Power F2 recall: Firmware issue may result in intermittent loss or degradation of powered
Firmware issue may result in intermittent loss or degradation of powered functionality when paired with compatible stretcher. The issue may lead to…
-
Class II · 10 days ago
Howmedica Osteonics Corp. Triathlon Hinge Femoral Prep Tray recall: Reprocessing instructions provided in LSTPI-B specify a sterilization dry
Reprocessing instructions provided in LSTPI-B specify a sterilization dry time of 30 minutes for the trays sterilized in blue wrap. When blue wrap is…
-
Class II · 10 days ago
Medline surgical convenience kits labeled as: 1) Open Heart Pack A & recall: Medical convenience kits were distributed containing cannula components
Medical convenience kits were distributed containing cannula components which do not conform to ISO 80369-7 dimensional requirements and may…
-
Class I · 10 days ago
Instrumentation Laboratory HemoslL AcuStar HIT-lgG recall: Potential for invalid calibration curve or negative mean bias of up to 47%
Potential for invalid calibration curve or negative mean bias of up to 47% with patient samples.
-
Class II · 10 days ago
Cook Incorporated Williams Cystoscopic Injection Needles recall: The female Luer lock adapter component in the affected device lots
The female Luer lock adapter component in the affected device lots may not have been correctly seated due to misalignment and inadequate torquing…